Series 360 EP


Swiss Made LCD Backlight Graphic Fully automatic calibration system SCS internal Easy alpha-numerical input Interface RS232 for PC Printer USB Device Communication options (USB host, bluetooth, wireless etc.) Support IQ/OQ/PQ Anti Theft protection, password plus mechanical security Direct tare entry (hand tare) direct reference weight entry Clock (printout GLP/GMP, Auto-Cal etc.) Below balance weighing
Units g, mg, ozt, lb, tael, etc. % weighing Counting program Animal weighing Density determination Check weighing plus/minus Net total application Add-up summation Dosage program Free conversion program Area conversion program (paper program) Statistics Recorder Min, sample weight Automatic repeatability test Multi-level-backweighing Dynamic Difference weighing Pipette calibration and evaporation trap Buoyancy error suppression technology
Model Capacity Readability Repeatability Linearity Pan Size
(mm/inch)
EP 125SM 125 g 0.01 mg 0.03 mg 0.06 mg Ø 80 / 3.1
EP 225SM-DR 102 g / 225 g 0.01 mg / 0.1 mg 0.03 / 0.1 mg 0.06 / 0.2 mg Ø 80 / 3.1

Series 360 ES


Swiss Made LCD Backlight Fully automatic calibration system SCS internal Interface RS232 for PC Printer Support IQ/OQ/PQ Anti Theft protection, password plus mechanical security Clock (printout GLP/GMP, Auto-Cal etc.) Below balance weighing
Units g, mg, ozt, lb, tael, etc. % weighing Counting program Animal weighing Density determination Check weighing plus/minus Net total application Add-up summation Dosage program Free conversion program Area conversion program (paper program) Statistics Recorder Min, sample weight Automatic repeatability test Multi-level-backweighing Dynamic Difference weighing Pipette calibration and evaporation trap Buoyancy error suppression technology
Model Capacity Readability Repeatability Linearity Pan Size
(mm/inch)
ES 125SM 125 g 0.01 mg 0.03 mg 0.06 mg Ø 80 / 3.1
ES 225SM-DR 102 g / 225 g 0.01 mg / 0.1 mg 0.03 / 0.1 mg 0.06 / 0.2 mg Ø 80 / 3.1

Series 320 XR


Swiss Made LCD Fully automatic calibration system SCS internal Interface RS232 for PC Printer Support IQ/OQ/PQ Anti Theft protection, password plus mechanical security Clock (printout GLP/GMP, Auto-Cal etc.) Below balance weighing
Units g, mg, ozt, lb, tael, etc. % weighing Counting program Animal weighing Density determination Check weighing plus/minus Net total application Add-up summation Dosage program Free conversion program Area conversion program (paper program) Statistics Recorder Min, sample weight Automatic repeatability test Multi-level-backweighing Dynamic Difference weighing Pipette calibration and evaporation trap Buoyancy error suppression technology
Model Capacity Readability Repeatability Linearity Pan Size
(mm/inch)
XR 125SM * 125 g 0.01 mg 0.03 mg 0.06 mg Ø 80 / 3.1
XR 125SM-FR * 41 g - 125 g 0.01 mg / 0.1 mg 0.03 / 0.1 mg 0.06 / 0.15 mg Ø 80 / 3.1
XR 205SM-DR * 92 g / 205 g 0.01 mg / 0.1 mg 0.03 / 0.1 mg 0.06 / 0.2 mg Ø 80 / 3.1

* models available with EC/OIML type approval


Sensor-controlled automatic draft shield which can be operated from left or right (manually operated)


Draft shield design provides optimum air-current suppression inside the weighing chamber


Draft shield design offers highest levels of user-ergonomics, including a large weighing chamber
Options 360 EP 360 ES 320 XR
Set for EC / OIML verification, fitted at factory, not verified,
available only for balances with EC (/ OIML) Type approval
EC-Verification according to 90/384/ECC by Precisa (initial verification)
available only for balances with EC (/ OIML) Type approval and SCS
SCS: Self Calibration System,
automatic on temperature change (and real-time programmable if clock installed)
standard standard standard
SCS fully: Self Calibration System,
automatic on temperature change and real-time programmable
standard standard standard
Clock standard standard standard
Accessories 360 EP 360 ES 320 XR
Draft shield 360 automatic standard -
Draft shield 360 automatic, height 180 mm -
Draft shield 360 manual standard -
Draft shield 360 manual, height 180 mm -
Draft shield 320 XT standard
Draft shield 320 XB, height 260mm
Draft shield 320 XB, height 180mm
Hook for weighing below the balance
Cable for balance 360 used as reference balance -
Cable for balance 320 used as reference balance - -
USV accu power pack, minimum 24 h continuous operation
Accupack complete 2 h continuous operation - - -
Power supply / Adapter with Euro plug
for balances with IP65 protection (80 V - 240 V)
Density kit for SM and A balances
Container size, Ø= 75 mm, h= 100 mm
Density kit solids only (without Glass body and Hook) for SM and A balances
Container size, Ø= 75 mm, h= 100 mm
Glass body, 10 ccm
Downholder for samples with density < 1 g/cm3
Evaporation trap for pipette calibration complete, for SM and A balances
Adapter to assemble Eppendorf Humidty Trap, for SM and A balances
Dust cover 360 for the whole balance, set of 20 pieces -
Dust cover 320 over display, set of 20 pieces - -
Dust cover 320 for the whole balance, set of 20 pieces - -
Night cover 320 for balance without draft shield - -
Night cover 320 for balance with draft shield - -
Series 360, slide-in modules 360 EP 360 ES
Precisa BUS converter, enables connection to almost all Precisa BUS accessories
USB Host -
Ethernet wired -
Ethernet wireless -
Bluetooth -
RS 485 -
CAN  
Additional Applications & Features
- SmartBox® Applications, see Special Accessories
- SmartBox® Applications, see Special Accessories
- Further special accessories and options, see Special Accessories
back to top »